    2x0.75 mm² Shielded Communication Cable [AE/MANG485R0H]
    2x0.75 mm² Shielded Communication Cable
    Ref.: AE/MANG485R0H
    Halogen free cable of 3 wires of 0.75 mm² (low capacity), shielded with an aluminium tape more a drain wire. Recommended for connections to RS-485 range of AGUILERA™ network. Complies with EN 50265-2-1, EN 50266, EN 50267-2 and EN50268 standards. Price per meter (Provided in 100 meters reels).
    V.A.T. included
    1.92 €
    2x1.5 mm² Halogen Free & Fire Resistant Cable [AE/MANG2RF30C]
    2x1.5 mm² Halogen Free & Fire Resistant Cable
    Ref.: AE/MANG2RF30C
    Complies with EN 50265, EN 50266, EN 50267, EN 50268, EN50200 standards. Halogen-free, flame retardant cable. Composed two wires (1.5 mm²) shielded with a aluminium tape and a polyester case, homologated for analogue system. Price per meter (Provided in 100 meters reels).
    V.A.T. included
    2.90 €
    2x1.5 mm² Halogen Free Cable [AE/MANG2R0HC]
    2x1.5 mm² Halogen Free Cable
    Ref.: AE/MANG2R0HC
    Complies with EN 50265, EN 50266, EN 50267, EN 50268 standards. Halogen-free, flame retardant cable. Composed two wires (1.5 mm²) shielded with a aluminium tape and a polyester case, homologated for analogue system. Price per meter (Provided in 100 meters reels).
    V.A.T. included
    Consult
    AGUILERA™ 1 Loop Algorithmic Panel [AE/SA-C1]
    AGUILERA™ 1 Loop Algorithmic Panel
    Ref.: AE/SA-C1
    Provided of 1 loop of 125 devices, where you can connect detectors, buttons, manoeuvre module, control and more elements that configure the installation. Switching power supply of 27,2VDC 2A. Emergency battery charger. Capacity for two batteries of 12V/7Ah. Dimensions: High 274 - Width 322 - Depth 123mm.
    V.A.T. included
    1,534.43 €
    AGUILERA™ 13.8VDC Buffered PSU -DIN Rail [AE/GI-AL101]
    AGUILERA™ 13.8VDC Buffered PSU -DIN Rail
    Ref.: AE/GI-AL101
    13.8Vdc power supply for charging the emergency battery.
    V.A.T. included
    360.48 €
    AGUILERA™ 13.8VDC PSU for Lithium Batteries - DIN Rail [AE/GI-AL102]
    AGUILERA™ 13.8VDC PSU for Lithium Batteries - DIN Rail
    Ref.: AE/GI-AL102
    Power supply for charging lithium emergency batteries.
    V.A.T. included
    360.48 €
    AGUILERA™ 2 Loops Algorithmic Panel [AE/SA-C2]
    AGUILERA™ 2 Loops Algorithmic Panel
    Ref.: AE/SA-C2
    Provided of 1 AE/SA-CTL card with 2 loops for 125 devices each, where you can connect detectors, buttons, manoeuvre module, control and more elements that configure the installation. Control Capacity up to 250 equipments. Switching power supply of 27.2VDC 4A. Emergency battery charger. Capacity for two 12V/7Ah batteries. Dimensions: High: 410- Width 310- Depth120mm.
    V.A.T. included
    1,915.71 €
    AGUILERA™ 2 Loops of 2 Wires Card [AE/SA-CTL]
    AGUILERA™ 2 Loops of 2 Wires Card
    Ref.: AE/SA-CTL
    Mircroprocessed control unit of two algorithmic loops. The capacity of each loop is about 125 devices, whcich you can connect detectors, push buttons, manoeuvre module, control module and more elements that configure the installation. Capacity to control a total of 250 devices. Dispose of light indicators for the control of correct operation and communication between devices and the panel.
    V.A.T. included
    315.56 €
    AGUILERA™ 2 Zones Panel in Metal Box [AE/C5-2M]
    AGUILERA™ 2 Zones Panel in Metal Box
    Ref.: AE/C5-2M
    Microprocessed metal panels, according to EN54 part 2 and 4. 2 conventional detection loops with active end of line. Access level control through keys. 2 EVACuation monitored output. Fire relay (General alarm) and general breakdown relay. 24VDC auxiliary output. keypad with 6 keys for management. "Zones test" mode. Individual connection/disconnection of detection zones and eVACuation zones. 10 Independent LEDs for alarm indications. Requires a unique 12V/7Ah battery. Continued monitoring of all the system. Dimensions AE/C5-2M: 200 x 290 x 80
    V.A.T. included
    Consult
    AGUILERA™ 2-Loop Analog Cards [AE/SA-TA]
    AGUILERA™ 2-Loop Analog Cards
    Ref.: AE/SA-TA
    Two analog loop control unit with independent microprocessor. The capacity of each loop is 125 pieces of equipment, to which the detectors, buttons, maneuver modules, control modules and other elements that make up the installation are connected. Total control capacity of 250 teams. It has light indicators to control the correct operation and communications with the equipment and the control unit.
    V.A.T. included
    Consult
    AGUILERA™ 24VDC PSU - DIN Rail [AE/GI-AL100]
    AGUILERA™ 24VDC PSU - DIN Rail
    Ref.: AE/GI-AL100
    24Vdc power supply for the CE100 system. 230 Vac input.
    V.A.T. included
    313.05 €
    AGUILERA™ 4 Zones Panel in Metal Box [AE/C5-4M]
    AGUILERA™ 4 Zones Panel in Metal Box
    Ref.: AE/C5-4M
    Microprocessed metal panels, according to EN54 part 2 and 4. 4 conventional detection loops with active end of line. Access level control through keys. 2 EVACuation monitored output. Fire relay (General alarm) and general breakdown relay. 24VDC auxiliary output. keypad with 6 keys for management. "Zones test" mode. Individual connection/disconnection of detection zones and eVACuation zones. 10 Independent LEDs for alarm indications. Requires a unique 12V/7Ah battery. Continued monitoring of all the system. Dimensions AE/C5-2M: 320 x 220 x 80.
    V.A.T. included
    Consult
    AGUILERA™ 50Kg Retainer [AE/V-R2450B15]
    AGUILERA™ 50Kg Retainer
    Ref.: AE/V-R2450B15
    Retainer 50 Kg/490N for floor with extendable arm from 15 to 18 cm, with traction plate, release button, 2 protection diodes. EN 1155 certified. Protection: IP40. Consumption: 45mA 24Vcc.
    V.A.T. included
    Consult
    AGUILERA™ 8 Zones Panel in ABS Box [AE/C5-8P]
    AGUILERA™ 8 Zones Panel in ABS Box
    Ref.: AE/C5-8P
    Similar feature than AE/C5-4P panel but with 8 conventional detection zones. Includes selection of push buttons zone or detectors zone, display output and connection to the module by AE/C5-R8 relay. Dimensions: 340X290X100. Allows the control by remote through AE/C5-IDC module and AGE44 telemonitoring software.
    V.A.T. included
    Consult
    AGUILERA™ 8, Expandable to 12 and 16 Zones Panel in Modular Hood [AE/C5-8-16]
    AGUILERA™ 8, Expandable to 12 and 16 Zones Panel in Modular Hood
    Ref.: AE/C5-8-16
    Microprocessed modular panel made according EN 54-2 and EN 54-4. Modular capacity between 8, 12 and 16 conventional detection zones with active end of line. 2 EVACuation monitored output. Fire and fauilure relay. Test zones mode. Control keys and LEDs for status indication. Capacity for 12V/18Ah battery. Dimensions: 462 X 345 X 120.
    V.A.T. included
    Consult
    AGUILERA™ Alarm Bell of 6" [AE/V-B6]
    AGUILERA™ Alarm Bell of 6"
    Ref.: AE/V-B6
    Metal alarm bell of 6" for indoors. Certified in accordance with EN54-3. Provided of micromotor to activate the ringing mechanism, red painted. Sound power: 95dB. Power supply: 24VDC. Consumption: 25mA. Weight: 0,45kg. Protection: IP21.
    V.A.T. included
    Consult
    AGUILERA™ Alarm Panel for Mobile Telephony [AE/AX30TRI]
    AGUILERA™ Alarm Panel for Mobile Telephony
    Ref.: AE/AX30TRI
    Fire control panel and external alarms repetition for three different operators. Contains power supply and battery charger. Fire detection loop. Automatic extinction control circuit which provides a monitored output the activation of an electrovalve. Relay output (24 V). 12 VDC output (500 mA.) for several purposes outside the panel unit. 30 external alarm input control, normally open or normally closed selectable by a commutator, (outputs for 30 alarms through potential-free relays normally open or closed selectable by a selector). For the first 14 outputs plus fire alarm and generl fail alarm there are three Sub-D connectors of 37 pins to be used independently by each operator. This information is simultaneously repeated in the three connectors. For the remaining 16 outputs, there is a single Sub-D, 37 pin connector. Repetition by two commuted 2 A relays, voltage free in outputs 1 and 30. Control of 1 FIRE output and 1 GENERAL FAIL output normally closed through the 3 first Sub-D ,37 pin connectors. 2 A commuted relays, voltage free for: Fire alarm, general fire alarm (normally energized); Ventilation stop, selectable with fire level 1 or 2; Optical and acoustic signals, as well as the necessary controls to manage the installation.
    V.A.T. included
    Consult
    AGUILERA™ Alarm Push Button for Outdoor [AE/V-PSIP]
    AGUILERA™ Alarm Push Button for Outdoor
    Ref.: AE/V-PSIP
    Conventional alarm push button appropriate for outdoor use, IP65 in accordance with EN54-11 standard. Dispose of micro-switch with load resistor of 470 ohm or 680 ohm, verification system with reset key and LED alarm. Allows the mounting of plastic plate calibrated to be located and don´t break or of breakable glass both provided. ABS box of 85 x 85 x 58 mm. Certified CE according to DPC. Certified LPCB. Protection: IP65.
    V.A.T. included
    Consult
    AGUILERA™ Alarm Push Button with Self-Check [AE/V-PSAT]
    AGUILERA™ Alarm Push Button with Self-Check
    Ref.: AE/V-PSAT
    Developped and made by AGUILERA™ Electrónica in accodance with EN54-11 standard. Equipped with: Micro-switch, Alarm and Self-Check LED, verification system with reset key, plastic plate calibrated to be located and don"t break. Push button with protection cover. Placed in ABS box. Certified CE emitted by LPCB. Dimensions: 98 x 95 x 39 mm.
    V.A.T. included
    Consult
    AGUILERA™ Algorithmic Detector Base with Sounder + Spotlight [ AE/SA-ASG3]
    AGUILERA™ Algorithmic Detector Base with Sounder + Spotlight
    Ref.: AE/SA-ASG3
    Base for algorithmic detector equipped with siren and low consumption light bulb. The siren and the focus are powered at 24 Vdc from a monitored output module of the algorithmic control unit. The detector is connected to the socket's own connectors. Maximum consumption 10 mA. Sound level 90 dB (A).
    V.A.T. included
    163.66 €