    A1 Custom Graphic Repeater Panel /w Facia & Box [GST8903-A1]
    A1 Custom Graphic Repeater Panel /w Facia & Box
    Ref.: GST8903-A1
    A1 Custom Graphic Repeater Panel /w Facia & Box
    V.A.T. included
    Consult
    A2 Custom Graphic Repeater Panel /w Facia & Box [GST8903-A2]
    A2 Custom Graphic Repeater Panel /w Facia & Box
    Ref.: GST8903-A2
    A2 Custom Graphic Repeater Panel /w Facia & Box
    V.A.T. included
    Consult
    AC Control Relay Module for UTC™ GST® Power Switching [C-9302]
    AC Control Relay Module for UTC™ GST® Power Switching
    Ref.: C-9302
    The C-9302 interposing relay module is used for interposing ordinary fire alarm devices with heavy duty (high voltage or heavy current) application, to prevent from interference and damage. It’s a non-addressable module, controlled by 24VDC.
    V.A.T. included
    72.26 €
    Base Mounted Isolator for UTC™ GST® 'I' Range Detectors [C-9504E]
    Base Mounted Isolator for UTC™ GST® 'I' Range Detectors
    Ref.: C-9504E
    In loop type fire alarm system, it often occurs that partial short circuit of loop affects the whole system. C-9504E Base Mount Short Circuit Isolator can isolate the shorted circuit from the whole system to ensure normal operation of the remaining parts and locate the failed part by illuminating a yellow indicator. When the short circuit fault is cleared, the shorted part will be restored. The isolator is applicable to all loop type fire alarm systems, either Class A or Class B loop.
    V.A.T. included
    38.33 €
    Base Mounted Isolator for UTC™ GST® Digitial Innovation Range Detectors [DC-9504E]
    Base Mounted Isolator for UTC™ GST® Digitial Innovation Range Detectors
    Ref.: DC-9504E
    In loop type fire alarm system, such condition often occurs that partial short circuit of loop affects the whole system. DC-9504E Base Mount Isolator can isolate the shorted circuit from the whole system and light the yellow LED to ensure normal operation of other parts and locate the part in fault. After the fault is cleared, the part of the loop will be re-included into the system. The isolator is applicable to both Class A and Class B fire alarm systems.
    V.A.T. included
    39.46 €
    CAN Network Card for UTC™ GST® GST-IFP8 (Class-A) [P-9965A]
    CAN Network Card for UTC™ GST® GST-IFP8 (Class-A)
    Ref.: P-9965A
    P-9965A network card provides CAN Class A network connection to GST-IFP8 panel. All panels are connected in peer to peer topology. In case of cable break among the network, there is still redundancy communication route. Compatible Panel: GST-IFP8 panel Communication Protocol: CAN. Node capacity: 99. Baud Rate: 10,000. Cable Requirement: Minimum 1.0 mm2 Fire Cable Communication Distance: 3000 meters.
    V.A.T. included
    Consult
    CAN Network Card for UTC™ GST® GST-IFP8 (Class-B) [P-9965]
    CAN Network Card for UTC™ GST® GST-IFP8 (Class-B)
    Ref.: P-9965
    P-9965 is an optional card for GST-IFP8 series control panels, providing one photoelectric isolation CAN interface for bus topology and star topology networks. P-9965 CAN Network Card should be fixed in the slot of Loop Board on the motherboard. These cards form ring network through twisted pair.
    V.A.T. included
    251.05 €
    CAN Network Card for UTC™ GST® GST200-2 (Class A) [P-9960A]
    CAN Network Card for UTC™ GST® GST200-2 (Class A)
    Ref.: P-9960A
    P-9960A is an optional card for GST200 series control panels, providing two photoelectric isolation CAN interfaces. Suitable for ring network. P-9960A CAN Network Card should be fixed in the cabinet using screws. These cards form ring network through twisted pair.
    V.A.T. included
    419.70 €
    CAN Network Card for UTC™ GST® GST200-2 (Class B) [P-9960]
    CAN Network Card for UTC™ GST® GST200-2 (Class B)
    Ref.: P-9960
    P-9960 network card provides CAN network connection to GST200 series panels. All panels are connected in same line. With CAN Hub, the network can be connected in star topology. Compatible Panel: GST200 series panels Communication Protocol: CAN. Node capacity: 112. Baud Rate: 10,000. Cable Requirement: Minimum 1.0 mm2 Fire Cable Communication Distance: 3000 meters.
    V.A.T. included
    350.96 €
    Dual Loop Card for UTC™ GST® GST-IFP8 [LCIFP8]
    Dual Loop Card for UTC™ GST® GST-IFP8
    Ref.: LCIFP8
    System expansion card for GST-IFP8 panel, adds two additional loops. Operation voltage: 24VDC. Operation current: 600mA. Capacity: 484 addresses. Loop Connection: Class A. Cable Requirement: Minimum 1.0mm2 Fire Cable Installation: Insert into typical slot of GST-IFP8.
    V.A.T. included
    901.87 €
    Intelligent 1 Loop Addr. CIE, 8 Zone, Built-in Printer, Integrated PSU /w Battery Charger, Excl. Batteries [GST100]
    Intelligent 1 Loop Addr. CIE, 8 Zone, Built-in Printer, Integrated PSU /w Battery Charger, Excl. Batteries
    Ref.: GST100
    Excellent cost effective replacement to conventional. Aesthetically attractive design. Loop capacity 128 addressable devices. LCD Display and LED indication. 8 Zone indication. Programmable via panel keyboard. Easy to use and simple to programme. Advanced user friendly programming of Zones and Pre-alarm. Built-in Panel Printer. Optional RS 485 Communication Protocol.
    V.A.T. included
    535.87 €