    UTC™ GST® Innovation Standard  Detector Base for Addressable and Conventional (when using EOLR) [DB-01]
    UTC™ GST® Innovation Standard Detector Base for Addressable and Conventional (when using EOLR)
    Ref.: DB-01
    DB-01 Base is used to mount digital and innovation conventional smoke, heat and combination detectors as their conductive base. It’s made of flame-resistant plastic ABS. It features attractive appearance, novel structure and stable performance. Its flame class is V-0. During installation, you can easily fix the base before connecting cables, and then twist the detector onto the base.
    V.A.T. included
    5.47 €
    UTC™ GST® Intelligent Addr. PSU (24VDC 10A) [PSU24-10A]
    UTC™ GST® Intelligent Addr. PSU (24VDC 10A)
    Ref.: PSU24-10A
    24 volt DC intelligent PSU, 10 ampere version. Digital display showing output voltage and load current. Fully monitored with output protection. Addressable intelligence for monitoring and reporting to main fire alarm panel. Mains supply 110 ~ 230VAC, 50/60Hz. Max. Battery Size: 24VDC /24AH sealed lead battery. Dimension: 520 x 350 x 156 mm.
    V.A.T. included
    Consult
    UTC™ GST® Intelligent Addr. PSU (24VDC 5A) [PSU24-5A]
    UTC™ GST® Intelligent Addr. PSU (24VDC 5A)
    Ref.: PSU24-5A
    24 volt DC intelligent PSU, 5 ampere version. Digital display showing output voltage and load current. Fully monitored with output protection. Addressable intelligence for monitoring and reporting to main fire alarm panel. Mains supply 230VAC (+10/-15%), 50Hz. Max. Battery Size: 24VDC /12AH sealed lead battery. Dimension: 400 x 318 x 128 mm.
    V.A.T. included
    Consult
    UTC™ GST® Intelligent Addr. Remote Indicator [ I-9314]
    UTC™ GST® Intelligent Addr. Remote Indicator
    Ref.: I-9314
    I-9314 intelligent door lamp is used to display the alarms of indoor detectors. It is usually installed on sites easy to view, such as above the door of meeting room, dining room and bedroom. When the indoor detector alarms, the LED on the lamp will flash so that personnel can know the detector has been triggered alarm without entering the room.
    V.A.T. included
    69.90 €
    UTC™ GST® Intelligent Addr. Single Input Module, Loop Powered [I-9300]
    UTC™ GST® Intelligent Addr. Single Input Module, Loop Powered
    Ref.: I-9300
    I-9300 Addressable Input Module is designed to receive normally open or normally closed switch signal from fire devices with coincidence functions, and transmits these messages to fire alarm control panel (FACP) with coincidence detection function. When a device of this kind is activated, the module can send the output signal through signal loop to FACP to alarm or activate relative devices.
    V.A.T. included
    56.88 €
    UTC™ GST® Intelligent Addr. Sounder (24VDC) [I-9404]
    UTC™ GST® Intelligent Addr. Sounder (24VDC)
    Ref.: I-9404
    The I-9404 is a detachable, surface mounted sounder. The audio efficiency and sound distribution generate over 85 dB at 3 meter distance giving an excellent audibility from the device location. The GST sounder series are convenient plug and turn installing method, two part construction with base mounted termination allows easy installation and avoiding the wiring and connection problem associated with traditional sounder.
    V.A.T. included
    119.80 €
    UTC™ GST® Intelligent PSU (24VDC 10A, Excl. Batteries) [PSU24-10]
    UTC™ GST® Intelligent PSU (24VDC 10A, Excl. Batteries)
    Ref.: PSU24-10
    24 volt DC intelligent PSU, 10 ampere version. Digital display showing output voltage and load current. Fully monitored with output protection. Mains supply 110 ~ 230VAC, 50/60Hz. Max. Battery Size: 24VDC /24AH sealed lead battery. Dimension: 520 x 350 x 156 mm.
    V.A.T. included
    Consult
    UTC™ GST® Intelligent PSU (24VDC 5A /w Display, Excl. Batteries) [PSU24-5]
    UTC™ GST® Intelligent PSU (24VDC 5A /w Display, Excl. Batteries)
    Ref.: PSU24-5
    24 volt DC intelligent PSU, 5 ampere version. Digital display showing output voltage and load current. Fully monitored with output protection. Mains supply 230VAC (+10/-15%), 50Hz. Max. Battery Size: 24VDC /12AH sealed lead battery. Dimension: 400 x 318 x 128 mm.
    V.A.T. included
    Consult
    UTC™ GST® Loop Isolator Module [DC-9503E]
    UTC™ GST® Loop Isolator Module
    Ref.: DC-9503E
    Isolation of short circuit, automatic restore when short circuit is cleared. Din-Rail mount, Surface mount. LED status indication. Standard: EN 54-17:2005. LPCB Approved. Operating Voltage: Loop 24VDC (16VDC - 28VDC). Standby Current? 0.15mA. Action Current? 1.5mA. Capacity: Maximum 128 isolators per loop. Maximun 70 devices between two isolators. Operating Environment: 0? - +49?; ? 95%, non-condensing. Dimension: 78 x 45.3 x 28.5 mm.
    V.A.T. included
    79.17 €
    UTC™ GST® Loop Monitor Module [DI-9319E]
    UTC™ GST® Loop Monitor Module
    Ref.: DI-9319E
    Input port cable monitoring with 4.7K? EOLR. Monitoring power supply. Two indicators for fire and fault. Normally-open or Normally-close output automatically follows input port to change state. Electronically addressed. Addresses can be modified in field. LED status indication. Din-Rail mount or surface mount. Standard: EN 54-18:2005. LPCB Approved.
    V.A.T. included
    121.22 €
    UTC™ GST® Monitor Input Module [DI-9305E]
    UTC™ GST® Monitor Input Module
    Ref.: DI-9305E
    Input port monitored. Output port monitored with 47K? EOLR. Double-contact relay switching 2 lines together. Electronically addressed. Addresses can be modified in field. Output port utilizes AD sampling technology for precise testing. LED status indication. Din-Rail mount, Surface mount. Standard: EN 54-18:2005. LPCB Approved.
    V.A.T. included
    132.36 €
    UTC™ GST® Portable Programming Tool [P-9910B]
    UTC™ GST® Portable Programming Tool
    Ref.: P-9910B
    The P-9910 GST protocol programming tool, capable of reading and writing address codes, displaying model number, year of manufacture and batch number, plus display and adjust analogue sensitivity. Enable to adjust alarm threshold, N/C or N/O and switch on or off the rate of rise of dual heat detector.
    V.A.T. included
    275.98 €
    UTC™ GST® Relay Board for GST102A [RB102A]
    UTC™ GST® Relay Board for GST102A
    Ref.: RB102A
    For zonal fault & fire alarm signal output. The relay board for conventional panel, provides additional signal outputs foe zonal fire and fault conditions. In case of fire or fault occurs in any zone, the corresponding relay will be activated, so that the conventional system can be integrated to 3rd party system. Output mode: normally open dry contact. Output capacity: 3A/24VDC/125VAC. WEEE & RoHS compliant. Standards: CE / CPD / EN54-2 / EN54-4. Certifications: LPCB. BS5839-1 compliant.
    V.A.T. included
    55.20 €
    UTC™ GST® Relay Board for GST104A [RB104A]
    UTC™ GST® Relay Board for GST104A
    Ref.: RB104A
    For zonal fault & fire alarm signal output. The relay board for conventional panel, provides additional signal outputs foe zonal fire and fault conditions. In case of fire or fault occurs in any zone, the corresponding relay will be activated, so that the conventional system can be integrated to 3rd party system. Output mode: normally open dry contact. Output capacity: 3A/24VDC/125VAC. WEEE & RoHS compliant. Standards: CE / CPD / EN54-2 / EN54-4. Certifications: LPCB. BS5839-1 compliant.
    V.A.T. included
    86.41 €
    UTC™ GST® Relay Board for GST108A [RB108A]
    UTC™ GST® Relay Board for GST108A
    Ref.: RB108A
    For zonal fault & fire alarm signal output. The relay board for conventional panel, provides additional signal outputs foe zonal fire and fault conditions. In case of fire or fault occurs in any zone, the corresponding relay will be activated, so that the conventional system can be integrated to 3rd party system. Output mode: normally open dry contact. Output capacity: 3A/24VDC/125VAC. WEEE & RoHS compliant. Standards: CE / CPD / EN54-2 / EN54-4. Certifications: LPCB. BS5839-1 compliant.
    V.A.T. included
    154.83 €
    UTC™ GST® Relay Board for GST116A [RB116A]
    UTC™ GST® Relay Board for GST116A
    Ref.: RB116A
    For zonal fault & fire alarm signal output. The relay board for conventional panel, provides additional signal outputs foe zonal fire and fault conditions. In case of fire or fault occurs in any zone, the corresponding relay will be activated, so that the conventional system can be integrated to 3rd party system. Output mode: normally open dry contact. Output capacity: 3A/24VDC/125VAC. WEEE & RoHS compliant. Standards: CE / CPD / EN54-2 / EN54-4. Certifications: LPCB. BS5839-1 compliant.
    V.A.T. included
    345.54 €
    UTC™ GST® Remote Indicator [C-9314P]
    UTC™ GST® Remote Indicator
    Ref.: C-9314P
    The C-9314P Remote Indicator is used to display an alarm from a detector. Suitable applications include when a detector is installed inside a room, false ceiling or an under floor cable space. When the detector issues an alarm, the LED on the lamp will light indicating where the detector was triggered.
    V.A.T. included
    16.25 €