English
Español
  • Search
  • 0.00 €

    Public audio

    Products 701
    LDA® RCD-21R Multifunction Player [LDARCD21RS03]
    LDA® RCD-21R Multifunction Player
    Ref.: LDARCD21RS03
    Multi-source player with DVD player, USB, SD and radio. Compatible with MP3 files. Independent outputs DVD / USB / SD and FM / AM radio. You can play music and radio in two zones at the same time. Includes mixed RCA audio .output. Independent volume controllers by output. Supports CDs, videos on DVD and JPEG images. Includes high-speed USB 2.0 port and SD cards. RS-485 remote control interface. Power supply 230V AC 50 / 60Hz. 1U of rack. Dimension 482 x 44 x 252 mm
    V.A.T. included
    710.11 €
    LDA® VAP-8K Expansion Module [LDAVAP8KS01]
    LDA® VAP-8K Expansion Module
    Ref.: LDAVAP8KS01
    It adds 8 extra programmable buttons that can be asigned to different zones by the configuration software. It includes transparent cover for zone's names indication. Up to 7 VAP-8K units per VAP-1 panel.
    V.A.T. included
    633.33 €
    LDA® VAP-1 Emergency and Events Panel [LDAVAP1S02]
    LDA® VAP-1 Emergency and Events Panel
    Ref.: LDAVAP1S02
    The Voice Alarm Panel VAP 1 is designed to provide NEO with evacuation system controls for different areas. It allows to know the condition of the system and broadcast both live and pre-recorded alarm and evacuation warnings through up to 56 selection memories of evacuation zones. This is possible because it can equip up to 7 expansion keyboards with 8 zone memories each one. Moreover, expansion keyboards available allow it to adjust to the special features of each system.
    V.A.T. included
    833.02 €
    LDA® VCC-64 Channel and Volume Controller [LDAVCC64S02]
    LDA® VCC-64 Channel and Volume Controller
    Ref.: LDAVCC64S02
    The VCC-64 allows up to 99 programmable channels and volume control (0-9). Usually installed in local zone and connected via bus to the system, it offers source selection, volume control and lock function. Installation in local zone and connected via bus to the system. 99 programmable channels. Volume control (0-9). Bus RS-485. 4 P terminal block. DIP switch. LCD Display of 2x8 character type.
    V.A.T. included
    308.82 €
    LDA® TFL Line Terminator [LDATFL1S01]
    LDA® TFL Line Terminator
    Ref.: LDATFL1S01
    It provides an accurate measurement of the speakers line impedance in order to test the integrity of the connection between the speakers and the PA/VA system. It is a compact device very simple to install in 100V or 70V lines. It has a low power consumption and several devices can be connected to the same speakers line.
    V.A.T. included
    Consult
    LDA® MPS-8K Expansion Module [LDAMPS8KS01]
    LDA® MPS-8K Expansion Module
    Ref.: LDAMPS8KS01
    It adds 8 extra programmable buttons that can be asigned to different zones by the configuration software. It includes transparent cover for
    V.A.T. included
    635.84 €
    LDA® NEO™ 8250-E Control Extension + Amplifier [LDANEO8250ES01]
    LDA® NEO™ 8250-E Control Extension + Amplifier
    Ref.: LDANEO8250ES01
    The amplification extension for the LDA NEO Evacuation Voice Alarm System includes 8 class D amplifiers of 250W per channel in 100V / 70V lines. Allows A + B connection. 8 pre-amplified outputs. Balanced audio Triple Ethernet port for Cobranet Digital Audio transmission, remote control and supervision as well as redundant cascade connection with NEO or other NEO Extensions.
    V.A.T. included
    7,156.62 €
    LDA® NEO™ 8060 Voice Evacuation System [LDANEO8060S02]
    LDA® NEO™ 8060 Voice Evacuation System
    Ref.: LDANEO8060S02
    LDA NEO 8060 is a compact EN 54-16 certified PA/VA system that ensures a ensures a fast, safe and controlled emergency evacuation. 5 audio inputs. 8 class D amplifiers with two configurations for 100V/70V lines: 8 class D amplifiers of 120W per channel or 4 class D amplifiers of 250W per channel. Audio Matrix 7x8 (digital up to 39x2014). 8 pre-amp outputs for external PA amplifiers connection. Up to 8 multi-zone microphones MPS-8Z or VAP-1 panels connected with CAT5 UTP cable. DSP: 7-band input/output Parametric Equalizer, loudness, LDA sound enhancer, independent volume control per each I/0 channel and audio filters. Triple Ethernet port: for Digital Audio Cobranet, remote control and supervision, and for escalating the system with NEO-Extensions in daisy-chain mode with Flexnet techlogy (up to 1024 zones). 4,3" Frontal touch screen with access control. 4GB of internal memory for pre-recorded messages. Integrated emergency microphone. Control for up to 32 attenuators LDA AT6. Integrated frontal loudspeaker for monitoring. 22 GPIO ports (8 supervised for integration with Fire Alarm Control Panel).
    V.A.T. included
    7,673.63 €
    4EVAC-RS422 Adapter Cable for PC Connection (4E-C500-RS422) [J530CA]
    4EVAC-RS422 Adapter Cable for PC Connection (4E-C500-RS422)
    Ref.: J530CA
    4EVAC-RS422 Adapter Cable for PC Connection.
    V.A.T. included
    579.53 €
    4EVAC™ 4E-GPIO Control Module with 16 Inputs and 16 Outputs [J519ES16]
    4EVAC™ 4E-GPIO Control Module with 16 Inputs and 16 Outputs
    Ref.: J519ES16
    Remote contact interface with following hardware configuration EN54-16; DIN-RAIL. Max. of 2x GPIO sharing 1x L-Net connection for communication and power purpose (Without additional 24VDC power Injector). 16 programmable monitored inputs. 16 programmable outputs. 2W DC aux output (max. 200mA @ 24VDC). Firemens microphone input, 4E-FMP. RS485 datalink with: (1) Balanced analogue audio input, (2) General Fault and EVAC status output, (3) Redundant L-Net link (max. 250m), 2xRJ45 (4) Addressable: 0-255.
    V.A.T. included
    1,999.16 €
    4EVAC™ 4E-SW6 Module for 6 Zones [J520Z6]
    4EVAC™ 4E-SW6 Module for 6 Zones
    Ref.: J520Z6
    The 4E-SW6 switch module routes evacuation and / or alert messages, location and music announcements (BGM) to six lines of loudspeakers. Adding more 4ESW6 switch modules adds to the system the ability to get any multiple of six speaker lines, grouped into virtual zones / groups. By adding end-of-line (EOL) modules to the loudspeaker lines, the 4E-SW6 monitors and detects faults as indicated in the EN 54 standard. Dimensions 65 x 90 x 118 mm.
    V.A.T. included
    1,186.02 €
    4EVAC™ DCA 2,500 Class D 2x500W Amplifier with EN-54 [J555A2500]
    4EVAC™ DCA 2,500 Class D 2x500W Amplifier with EN-54
    Ref.: J555A2500
    2 x 500 W RMS class D power stage with 4 A battery charger, managed from the 4EVAC-IMPACT system control unit. Up to 16 power stages with a total of 16,000 W can be used in an installation. To subdivide the power, the 4E-SW6 modules allow the creation of additional subzones. It occupies 2 units of rack height.
    V.A.T. included
    5,310.12 €
    4EVAC™ C500/3 All-In-One Public Address and Voice Alarm System - EN 54 600W with Backup [J516B]
    4EVAC™ C500/3 All-In-One Public Address and Voice Alarm System - EN 54 600W with Backup
    Ref.: J516B
    All-in-one voice alarm and evacuation system, with the simplicity of independent equipment and the benefits of a network topology to link and expand the system. Each C500 manages 6 audio streams that can be output simultaneously on the 6 speaker lines connected to the 100 W RMS power units. For global announcements, the C500s are linked in a network, by means of a redundant loop, with 2 audio channels and a serial data channel (RS485).
    V.A.T. included
    10,373.15 €
    4EVAC™ C500/2 All-In-One Public Address and Voice Alarm System - EN 54 400W with Backup [J514B]
    4EVAC™ C500/2 All-In-One Public Address and Voice Alarm System - EN 54 400W with Backup
    Ref.: J514B
    All-in-one voice alarm and evacuation system, with the simplicity of independent equipment and the benefits of a network topology to link and expand the system. Each C500 manages 6 audio streams that can be output simultaneously on the 6 speaker lines connected to the 100 W RMS power units. For global announcements, the C500s are linked in a network, by means of a redundant loop, with 2 audio channels and a serial data channel (RS485).
    V.A.T. included
    9,613.92 €
    4EVAC™ C500/1 All-In-One Public Address and Voice Alarm System - EN 54 200W with Backup [J512B]
    4EVAC™ C500/1 All-In-One Public Address and Voice Alarm System - EN 54 200W with Backup
    Ref.: J512B
    All-in-one voice alarm and evacuation system, with the simplicity of independent equipment and the benefits of a network topology to link and expand the system. Each C500 manages 6 audio streams that can be output simultaneously on the 6 speaker lines connected to the 100 W RMS power units. For global announcements, the C500s are linked in a network, by means of a redundant loop, with 2 audio channels and a serial data channel (RS485).
    V.A.T. included
    8,854.70 €
    4EVAC™ C500/3 All-In-One Public Address and Voice Alarm System - EN 54 600W [J506]
    4EVAC™ C500/3 All-In-One Public Address and Voice Alarm System - EN 54 600W
    Ref.: J506
    All-in-one voice alarm and evacuation system, with the simplicity of independent equipment and the benefits of a network topology to link and expand the system. Each C500 manages 6 audio streams that can be output simultaneously on the 6 speaker lines connected to the 100 W RMS power units. For global announcements, the C500s are linked in a network, by means of a redundant loop, with 2 audio channels and a serial data channel (RS485).
    V.A.T. included
    9,869.99 €
    4EVAC™ C500/2 All-In-One Public Address and Voice Alarm System - EN 54 400W [J504]
    4EVAC™ C500/2 All-In-One Public Address and Voice Alarm System - EN 54 400W
    Ref.: J504
    All-in-one voice alarm and evacuation system, with the simplicity of independent equipment and the benefits of a network topology to link and expand the system. Each C500 manages 6 audio streams that can be output simultaneously on the 6 speaker lines connected to the 100 W RMS power units. For global announcements, the C500s are linked in a network, by means of a redundant loop, with 2 audio channels and a serial data channel (RS485).
    V.A.T. included
    9,110.77 €
    4EVAC™ C500/1 All-In-One Public Address and Voice Alarm System - EN 54 200W [J502]
    4EVAC™ C500/1 All-In-One Public Address and Voice Alarm System - EN 54 200W
    Ref.: J502
    All-in-one voice alarm and evacuation system, with the simplicity of independent equipment and the benefits of a network topology to link and expand the system. Each C500 manages 6 audio streams that can be output simultaneously on the 6 speaker lines connected to the 100 W RMS power units. For global announcements, the C500s are linked in a network, by means of a redundant loop, with 2 audio channels and a serial data channel (RS485).
    V.A.T. included
    8,351.53 €
    SYSAWAY© 2024 All rights reserved