English
Español
  • Search
  • +34 902930427

    0.00 €

    Fire Detectors

    Products 623
    HONEYWELL™ Flow Detector 150mm (6”) Pipes [WFD60EN]
    HONEYWELL™ Flow Detector 150mm (6”) Pipes
    Ref.: WFD60EN
    Flow detector for 150mm pipes (6") with clamp anchor and disc in red color. Dispose of an adjustable delay mechanism, with a maximum adjustment of 30 seconds and a double switched circuit with voltage-free contacts (C/NA/NC). Flow direction indicator and audible relay.
    V.A.T. included
    Consult
    HONEYWELL™ Flow Detector 100mm (4”) Pipes [WFD40EN]
    HONEYWELL™ Flow Detector 100mm (4”) Pipes
    Ref.: WFD40EN
    Flow detector for 100mm pipes (4") with clamp anchor and disc in red color. Dispose of an adjustable delay mechanism, with a maximum adjustment of 30 seconds and a double switched circuit with voltage-free contacts (C/NA/NC). Flow direction indicator and audible relay.
    V.A.T. included
    Consult
    Pressure Switch for Fluids or Gases Supervision [EPS40-1]
    Pressure Switch for Fluids or Gases Supervision
    Ref.: EPS40-1
    Pressure switch for the supervision of liquids or gas hosted in pipes or deposits at high or low pressure (40-100PSI), with switched circuit with voltage free contacts (C/NA/NC).
    V.A.T. included
    Consult
    Pressure Switch for Fluids Supervision [EPS10-1]
    Pressure Switch for Fluids Supervision
    Ref.: EPS10-1
    Pressure switch for liquids supervision at low pressure (10PSI), Switched circuit with voltage-free contacts (C/NA/NC).
    V.A.T. included
    Consult
    HONEYWELL™ Flow Detector 200mm (8”) Pipes [WFD80EN]
    HONEYWELL™ Flow Detector 200mm (8”) Pipes
    Ref.: WFD80EN
    Flow detector for 200mm pipes (8") with clamp anchor and disc in red color. Dispose of an adjustable delay mechanism, with a maximum adjustment of 30 seconds and a double switched circuit with voltage-free contacts (C/NA/NC). Flow direction indicator and audible relay.
    V.A.T. included
    Consult
    HONEYWELL™Flow Detector 50mm (2”) Pipes [WFD20EN]
    HONEYWELL™Flow Detector 50mm (2”) Pipes
    Ref.: WFD20EN
    Flow detector for 50mm pipes (2") with clamp anchor and disc in red color. Dispose of an adjustable delay mechanism, with a maximum adjustment of 30 seconds and a double switched circuit with voltage-free contacts (C/NA/NC). Flow direction indicator and audible relay.
    V.A.T. included
    Consult
    HONEYWELL™ Flow Detector 80mm (3”) Pipes [WFD30EN]
    HONEYWELL™ Flow Detector 80mm (3”) Pipes
    Ref.: WFD30EN
    Flow detector for 80mm pipes (3") with clamp anchor and disc in red color. Dispose of an adjustable delay mechanism, with a maximum adjustment of 30 seconds and a double switched circuit with voltage-free contacts (C/NA/NC). Flow direction indicator and audible relay.
    V.A.T. included
    Consult
    HONEYWELL™ Flow Detector for 65mm (2,5”) Pipes [WFD25EN]
    HONEYWELL™ Flow Detector for 65mm (2,5”) Pipes
    Ref.: WFD25EN
    Flow detector for 65mm pipes (2,5") with clamp anchor and disc in red color. Dispose of an adjustable delay mechanism, with a maximum adjustment of 30 seconds and a double switched circuit with voltage-free contacts (C/NA/NC). Flow direction indicator and audible relay.
    V.A.T. included
    Consult
    NOTIFIER® Watertight Thermal Detector EN54/5 at 90ºC [TMP2DCS1A]
    NOTIFIER® Watertight Thermal Detector EN54/5 at 90ºC
    Ref.: TMP2DCS1A
    EN54/5 Thermal detector just as TMP2DA2S1A but with an activation range between 84ºC and 100ºC (Class C).
    V.A.T. included
    Consult
    NOTIFIER® Flameproof Probe EEx-d ATEX 110ºC [TMP2TODS1A]
    NOTIFIER® Flameproof Probe EEx-d ATEX 110ºC
    Ref.: TMP2TODS1A
    Self-healing thermal probe with activation range between 99ºC and 115ºC (Class D) mounted in a ATEX II 2G EEx-d IIC T6 box, with IP66 protection grade. Particularly suitable for installations with explosive atmospheres and exhaust ducts or zones with a presence of corrosive elements or condensing vapors. Appropriate for indoors and outdoors. Compatible with most of market conventional centrals and with HLSI analogical centrals through a zone module.
    V.A.T. included
    Consult
    EN54/5 Flameproof Thermal Detector NOTIFIER® EEx-d ATEX 90ºC [TMP2TOCS1A]
    EN54/5 Flameproof Thermal Detector NOTIFIER® EEx-d ATEX 90ºC
    Ref.: TMP2TOCS1A
    EN54/5 Thermal detector just as TMP2TOA2S1A but with a activation range between 84°C and 100°C (class C).
    V.A.T. included
    Consult
    NOTIFIER® Waterproof Probe at 110ºC [TMP2DDS1A]
    NOTIFIER® Waterproof Probe at 110ºC
    Ref.: TMP2DDS1A
    Self-healing thermal probe with an activation range between 99ºC and 115ºC (Class D) mounted in a watertight aluminium box with IP66 protection grade. Compatible with most of market conventional centrals and HLSI analogical centrals through a zone module.
    V.A.T. included
    Consult
    NOTIFIER® Watertight Thermal Detector EN54/5 at 57ºC [TMP2DA2S1A]
    NOTIFIER® Watertight Thermal Detector EN54/5 at 57ºC
    Ref.: TMP2DA2S1A
    EN54/5 Self-healing thermal detector with activation range between 54ºC and 70ºC (Class A). Mounted in a watertight aluminium box with IP66 protection grade. Appropriate for indoors and outdoors. Compatible with most of market conventional centrals and HLSI analogical centrals through a zone module. Complies with CPR construction product regulation.
    V.A.T. included
    Consult
    HONEYWELL® Analog Optical White Detector [TC806ES1012]
    HONEYWELL® Analog Optical White Detector
    Ref.: TC806ES1012
    Analogue addressable photoelectronic sensors are plug-in type smoke sensors that combine a photoelectronic sensing chamber with addressable-analogue communications. These sensors are designed for open area protection and must only be connected to control panels that use a compatible proprietary analogue addressable communciation protocol for monitoring and control.
    V.A.T. included
    Consult
    KILSEN® Inclemency Thermic Conventional Detector [6296]
    KILSEN® Inclemency Thermic Conventional Detector
    Ref.: 6296
    IP67 Conventional inclemency detectors, fixed temperature of 72ºC, Class BS (Ex II 3GD EEx nA II T5). Includes base with pipe input.
    V.A.T. included
    Consult
    KILSEN® Inclemency Thermic Conventional Detector [6295]
    KILSEN® Inclemency Thermic Conventional Detector
    Ref.: 6295
    IP67 Conventional inclemency detectors, fixed temperature of 57ºC, Class A2S (Ex II 3GD EEx nA II T5). Includes base with pipe input.
    V.A.T. included
    Consult
    KILSEN® Inclemency Thermic Conventional Detector [6298]
    KILSEN® Inclemency Thermic Conventional Detector
    Ref.: 6298
    IP67 Conventional inclemency detectors, fixed temperature of 117ºC, Class ES (Ex II 3GD EEx nA II T5). Includes base with pipe input.
    V.A.T. included
    Consult
    KILSEN® Speed Increasing Temperature Sensor [KV210]
    KILSEN® Speed Increasing Temperature Sensor
    Ref.: KV210
    Compact conventional thermovelocimetric detector with controller alarm indictaion with base and pipe supplements, watertight electronic and anti-theft module. Certified CPD in accordance with EN54 part 5 standards.
    V.A.T. included
    Consult
    UTC™ Aritech™ Analogic Wireless Optical Detector with Integrated Sounder [DP931AS-RF]
    UTC™ Aritech™ Analogic Wireless Optical Detector with Integrated Sounder
    Ref.: DP931AS-RF
    Wireless analogic optical smoke detector with integrated sounder, for Aritech™ analogical panels. Frequency 868Mhz. Includes base and batteries. It is powered by 6 AA batteries MN 1500 LR6, autonomy of up to 5 years. Dimensions: 146 x 84 mm. Certificates: CE and CPR (EN54 parts 3, 7 and 25).
    V.A.T. included
    Consult
    SYSAWAY© 2025 All rights reserved