English
Español
  • Search
  • 0.00 €

    PCI Centrals and Modules

    Products 406
    AGUILERA™ Direction Programmer with 9V Alkaline Battery [AE/SA-PRG]
    AGUILERA™ Direction Programmer with 9V Alkaline Battery
    Ref.: AE/SA-PRG
    Portable device to program the number of idendification code of each algorithm that allows to: Record the address of the equipment , read the stored adress, inhibit/authorize individually the LED flash of the device. The programmation process is individual for each device and can be done from the algorithm central.
    V.A.T. included
    128.07 €
    AGUILERA™ 2-Loop Analog Cards [AE/SA-TA]
    AGUILERA™ 2-Loop Analog Cards
    Ref.: AE/SA-TA
    Two analog loop control unit with independent microprocessor. The capacity of each loop is 125 pieces of equipment, to which the detectors, buttons, maneuver modules, control modules and other elements that make up the installation are connected. Total control capacity of 250 teams. It has light indicators to control the correct operation and communications with the equipment and the control unit.
    V.A.T. included
    Consult
    AGUILERA™ Master Module [AE/94-M]
    AGUILERA™ Master Module
    Ref.: AE/94-M
    Addressable module developed to control a series of conventional detectors or pushbuttons in a 2-wire controlled loop, which can correspond to a specific area, sector or room.
    V.A.T. included
    Consult
    AGUILERA™ Alarm Panel for Mobile Telephony [AE/AX30TRI]
    AGUILERA™ Alarm Panel for Mobile Telephony
    Ref.: AE/AX30TRI
    Fire control panel and external alarms repetition for three different operators. Contains power supply and battery charger. Fire detection loop. Automatic extinction control circuit which provides a monitored output the activation of an electrovalve. Relay output (24 V). 12 VDC output (500 mA.) for several purposes outside the panel unit. 30 external alarm input control, normally open or normally closed selectable by a commutator, (outputs for 30 alarms through potential-free relays normally open or closed selectable by a selector). For the first 14 outputs plus fire alarm and generl fail alarm there are three Sub-D connectors of 37 pins to be used independently by each operator. This information is simultaneously repeated in the three connectors. For the remaining 16 outputs, there is a single Sub-D, 37 pin connector. Repetition by two commuted 2 A relays, voltage free in outputs 1 and 30. Control of 1 FIRE output and 1 GENERAL FAIL output normally closed through the 3 first Sub-D ,37 pin connectors. 2 A commuted relays, voltage free for: Fire alarm, general fire alarm (normally energized); Ventilation stop, selectable with fire level 1 or 2; Optical and acoustic signals, as well as the necessary controls to manage the installation.
    V.A.T. included
    Consult
    AGUILERA™ Communications Interface [AE/C5-IDC]
    AGUILERA™ Communications Interface
    Ref.: AE/C5-IDC
    Interface board to integrate AE/C5-8-16 and AE/C5-8P panels in AGE44 remote control program. Integration realized through TCP/IP. This board its connected into the controlled panel.
    V.A.T. included
    Consult
    AGUILERA™ Module of 8 Relay Outputs [AE/C5-R8]
    AGUILERA™ Module of 8 Relay Outputs
    Ref.: AE/C5-R8
    Module of 8 remote relay for AE/C5-8-16 panel. Provided with NA or NC voltage free contact, individually selectable through a jumper. Realys are individually activated in case of zone alarm. The module requires 24VDC extern power supply. 4 or 6 Wires connection (If its power supplied from the panel). Maximum panel distance 1000m, maximum number of modules:2.
    V.A.T. included
    Consult
    AGUILERA™ Expandable Card of 4 Zones [AE/C5-MZ4]
    AGUILERA™ Expandable Card of 4 Zones
    Ref.: AE/C5-MZ4
    To expand the panel to 12 zones: a AE/C5-8-16 panel and a AE/C5-MZ4 4 zones card.
    V.A.T. included
    Consult
    AGUILERA™ Expandable Card of 4 Outputs [AE/C5-MS4]
    AGUILERA™ Expandable Card of 4 Outputs
    Ref.: AE/C5-MS4
    To expand the panel to 16 zones: a AE/C5-8-16 panel and two AE/C5-MZ4 4 zones cards.
    V.A.T. included
    Consult
    AGUILERA™ 8, Expandable to 12 and 16 Zones Panel in Modular Hood [AE/C5-8-16]
    AGUILERA™ 8, Expandable to 12 and 16 Zones Panel in Modular Hood
    Ref.: AE/C5-8-16
    Microprocessed modular panel made according EN 54-2 and EN 54-4. Modular capacity between 8, 12 and 16 conventional detection zones with active end of line. 2 EVACuation monitored output. Fire and fauilure relay. Test zones mode. Control keys and LEDs for status indication. Capacity for 12V/18Ah battery. Dimensions: 462 X 345 X 120.
    V.A.T. included
    Consult
    AGUILERA™ 4 Zones Panel in Metal Box [AE/C5-4M]
    AGUILERA™ 4 Zones Panel in Metal Box
    Ref.: AE/C5-4M
    Microprocessed metal panels, according to EN54 part 2 and 4. 4 conventional detection loops with active end of line. Access level control through keys. 2 EVACuation monitored output. Fire relay (General alarm) and general breakdown relay. 24VDC auxiliary output. keypad with 6 keys for management. "Zones test" mode. Individual connection/disconnection of detection zones and eVACuation zones. 10 Independent LEDs for alarm indications. Requires a unique 12V/7Ah battery. Continued monitoring of all the system. Dimensions AE/C5-2M: 320 x 220 x 80.
    V.A.T. included
    Consult
    AGUILERA™ 8 Zones Panel in ABS Box [AE/C5-8P]
    AGUILERA™ 8 Zones Panel in ABS Box
    Ref.: AE/C5-8P
    Similar feature than AE/C5-4P panel but with 8 conventional detection zones. Includes selection of push buttons zone or detectors zone, display output and connection to the module by AE/C5-R8 relay. Dimensions: 340X290X100. Allows the control by remote through AE/C5-IDC module and AGE44 telemonitoring software.
    V.A.T. included
    Consult
    AGUILERA™ 2 Zones Panel in Metal Box [AE/C5-2M]
    AGUILERA™ 2 Zones Panel in Metal Box
    Ref.: AE/C5-2M
    Microprocessed metal panels, according to EN54 part 2 and 4. 2 conventional detection loops with active end of line. Access level control through keys. 2 EVACuation monitored output. Fire relay (General alarm) and general breakdown relay. 24VDC auxiliary output. keypad with 6 keys for management. "Zones test" mode. Individual connection/disconnection of detection zones and eVACuation zones. 10 Independent LEDs for alarm indications. Requires a unique 12V/7Ah battery. Continued monitoring of all the system. Dimensions AE/C5-2M: 200 x 290 x 80
    V.A.T. included
    Consult
    SYSAWAY© 2024 All rights reserved