    AGUILERA™ Optical-Thermal Detector [AE/C5-OPT]
    AGUILERA™ Optical-Thermal Detector
    Ref.: AE/C5-OPT
    Optic smoke and heat thermal detector (class A). Certified LPCB according to EN54-5 and EN 54-7 standards. Low perfil detectors with attractive design. Made with SMD technology, provided of a double light indicator, remote alarm output and with the same interchangeable base for easy connection. Socket and powder protector included. 2 Wires connection. Power supply between 15 and 35 VDC. Consumption: 35 ?A (Standby), 80mA (Alarm). Dimensions: Ø 99 mm, high with base included: 61mm.
    V.A.T. included
    Consult
    AGUILERA™ Optic Smoke Detector [AE/C5-OP]
    AGUILERA™ Optic Smoke Detector
    Ref.: AE/C5-OP
    Optic smoke detector certified LPCB according to EN 54-7 standard. Low perfil detectors with attractive design. Made with SMD tehnology, provided of a double light indicator, remote alarm output with the same interchangeable base for easy connection. Socket and powder protector included. 2 Wires connection. Power supply between 15 and 35 VDC. Consumption: 35 ?A (Standby), 80mA (Alarm). Dimensions: Ø 99 mm, high with base included: 46mm.
    V.A.T. included
    Consult
    Base for AGUILERA™ Analogical Detector Provided of a Sounder [AE/SA-ASG3S]
    Base for AGUILERA™ Analogical Detector Provided of a Sounder
    Ref.: AE/SA-ASG3S
    Base for algorithmic detector provided of sounder. The sounder is power supplied at 24VDC from a monitored output module from the algorithmic central. The detector connection is realized in the socket connectors. Maximum consumption of 5mA. Sound level 90dB (A).
    V.A.T. included
    83.25 €
    Base for AGUILERA™ Algorithmic Detector Provided of Sounder with Focus [AE/SA-ASG3]
    Base for AGUILERA™ Algorithmic Detector Provided of Sounder with Focus
    Ref.: AE/SA-ASG3
    Base for algorithmic detector provided of sounder and low consumption luminous focus. The sounder and the focus are power supply at 24VDC from a monitored output module of the algorithmic central. The detector connection are realized in the socket connectors. Maximum consumption of 10mA. Sound level 90dB (A).
    V.A.T. included
    163.66 €
    Socket for AGUILERA™ Algorithmic Detectors [AE/SA-ZB2]
    Socket for AGUILERA™ Algorithmic Detectors
    Ref.: AE/SA-ZB2
    ABS socket made by AGUILERA™ ELECTRÓNICA, recyclable with ring and screw contacts, for cables connection, in stainless steel. Allows the exchange of all algorithmic detectors.
    V.A.T. included
    5.34 €
    Surface Supplement [AE/SA-ZS]
    Surface Supplement
    Ref.: AE/SA-ZS
    Mounting supplement for tubes. Easy to install allowing th input of 3 tubes of 20mm. Compatible with all algorithmic detectors. Made in ABS.
    V.A.T. included
    1.54 €
    AGUILERA™ Thermovelocimetric  Detector [AE/SA-T]
    AGUILERA™ Thermovelocimetric Detector
    Ref.: AE/SA-T
    Heat detector made by AGUILERA™ ELECTRÓNICA in accordance with UNE EN54-5 standard with CE certificate of conformity and AENOR quality mark. addressable algorithmic unit thant manage two temperature parameters: Differential and thermal. Both measure are analized and send to the central to take a alarm decision with the setting made in each case.
    V.A.T. included
    57.51 €
    AGUILERA™ Optical-Thermal Detector [AE/SA-OPT]
    AGUILERA™ Optical-Thermal Detector
    Ref.: AE/SA-OPT
    Multisensor detector with double technology, of smoke and heat, made by AGUILERA™ ELECTRÓNICA according to UNE EN 54-7 and UNE EN 54-5 standards with CE certificate of conformity and AENOR quality mark. addressable algorithmic unit that manage a optic smoke sensor and other of heat. The optic sensor take light measure that disperse smoke particles and its raise. All measurements are analized and sended to the central to take a alarm decision that always reaches the programmated parameters. Possess the same features than AE/SA-OP detector.
    V.A.T. included
    72.33 €
    AGUILERA™ Low Profile Optic Detector [AE/SA-OPI]
    AGUILERA™ Low Profile Optic Detector
    Ref.: AE/SA-OPI
    Features that give the distinction between the rest of optic detectors are its design and its dimensions. The AE/SA-OPI has a lower perfil, only 43mm high, that permit to be fixed closer to the roof. CE certificate of conformity according EN54-7 standard.
    V.A.T. included
    53.95 €
    AGUILERA™ Optic Detector [AE/SA-OP]
    AGUILERA™ Optic Detector
    Ref.: AE/SA-OP
    Smoke detector made by AGUILERA™ ELECTRÓNICA according to UNE EN 54-7 standards, with CE certificate of conformity and AENOR quality mark. addressable algorithmic unit that manage a optical smoke sensor. Its function is to tke light measures that disperse smoke particles, assess the density and the rate of increase in the time and to send an information to the analized central to take an alame decision when it reach the set parameters.
    V.A.T. included
    66.40 €
    AGUILERA™ Alarm Panel for Mobile Telephony [AE/AX30TRI]
    AGUILERA™ Alarm Panel for Mobile Telephony
    Ref.: AE/AX30TRI
    Fire control panel and external alarms repetition for three different operators. Contains power supply and battery charger. Fire detection loop. Automatic extinction control circuit which provides a monitored output the activation of an electrovalve. Relay output (24 V). 12 VDC output (500 mA.) for several purposes outside the panel unit. 30 external alarm input control, normally open or normally closed selectable by a commutator, (outputs for 30 alarms through potential-free relays normally open or closed selectable by a selector). For the first 14 outputs plus fire alarm and generl fail alarm there are three Sub-D connectors of 37 pins to be used independently by each operator. This information is simultaneously repeated in the three connectors. For the remaining 16 outputs, there is a single Sub-D, 37 pin connector. Repetition by two commuted 2 A relays, voltage free in outputs 1 and 30. Control of 1 FIRE output and 1 GENERAL FAIL output normally closed through the 3 first Sub-D ,37 pin connectors. 2 A commuted relays, voltage free for: Fire alarm, general fire alarm (normally energized); Ventilation stop, selectable with fire level 1 or 2; Optical and acoustic signals, as well as the necessary controls to manage the installation.
    V.A.T. included
    Consult
    AGUILERA™ Communications Interface [AE/C5-IDC]
    AGUILERA™ Communications Interface
    Ref.: AE/C5-IDC
    Interface board to integrate AE/C5-8-16 and AE/C5-8P panels in AGE44 remote control program. Integration realized through TCP/IP. This board its connected into the controlled panel.
    V.A.T. included
    Consult
    AGUILERA™ Module of 8 Relay Outputs [AE/C5-R8]
    AGUILERA™ Module of 8 Relay Outputs
    Ref.: AE/C5-R8
    Module of 8 remote relay for AE/C5-8-16 panel. Provided with NA or NC voltage free contact, individually selectable through a jumper. Realys are individually activated in case of zone alarm. The module requires 24VDC extern power supply. 4 or 6 Wires connection (If its power supplied from the panel). Maximum panel distance 1000m, maximum number of modules:2.
    V.A.T. included
    Consult
    AGUILERA™ Expandable Card of 4 Zones [AE/C5-MZ4]
    AGUILERA™ Expandable Card of 4 Zones
    Ref.: AE/C5-MZ4
    To expand the panel to 12 zones: a AE/C5-8-16 panel and a AE/C5-MZ4 4 zones card.
    V.A.T. included
    Consult
    AGUILERA™ Expandable Card of 4 Outputs [AE/C5-MS4]
    AGUILERA™ Expandable Card of 4 Outputs
    Ref.: AE/C5-MS4
    To expand the panel to 16 zones: a AE/C5-8-16 panel and two AE/C5-MZ4 4 zones cards.
    V.A.T. included
    Consult
    AGUILERA™ 8, Expandable to 12 and 16 Zones Panel in Modular Hood [AE/C5-8-16]
    AGUILERA™ 8, Expandable to 12 and 16 Zones Panel in Modular Hood
    Ref.: AE/C5-8-16
    Microprocessed modular panel made according EN 54-2 and EN 54-4. Modular capacity between 8, 12 and 16 conventional detection zones with active end of line. 2 EVACuation monitored output. Fire and fauilure relay. Test zones mode. Control keys and LEDs for status indication. Capacity for 12V/18Ah battery. Dimensions: 462 X 345 X 120.
    V.A.T. included
    Consult
    AGUILERA™ 4 Zones Panel in Metal Box [AE/C5-4M]
    AGUILERA™ 4 Zones Panel in Metal Box
    Ref.: AE/C5-4M
    Microprocessed metal panels, according to EN54 part 2 and 4. 4 conventional detection loops with active end of line. Access level control through keys. 2 EVACuation monitored output. Fire relay (General alarm) and general breakdown relay. 24VDC auxiliary output. keypad with 6 keys for management. "Zones test" mode. Individual connection/disconnection of detection zones and eVACuation zones. 10 Independent LEDs for alarm indications. Requires a unique 12V/7Ah battery. Continued monitoring of all the system. Dimensions AE/C5-2M: 320 x 220 x 80.
    V.A.T. included
    Consult