English
Español
  • Search
  • 0.00 €

    Fire

    Products 2730
    • Access Control Readers
    • Access Control Credentials
    • Access Control Credentials
    • Access Control Credentials
    • Access Control Credentials
    • Access Control Credentials
    • Access Control Credentials
    • Access Control Credentials
    NOTIFIER® Module of 1 Zone to Expand Park™ Panels [P-100]
    NOTIFIER® Module of 1 Zone to Expand Park™ Panels
    Ref.: P-100
    1 zone module to expand Park™ carbon monoxide detection panels. Each module support a maximum of 16 detectors and is provided with 10 status LEDs, 2 level relays and 1 alarm relay.
    V.A.T. included
    Consult
    MorleyIAS® Vision LT Conventional Panel - 12 Zones (Portuguese) [VSN12-LT-P]
    MorleyIAS® Vision LT Conventional Panel - 12 Zones (Portuguese)
    Ref.: VSN12-LT-P
    Microprocessed compact fire detection panel of 12 zones. Distinghuises between alarm detector or push buttons by zone. Up to 32 ECO1000 detectors by zone. Includes power supply, 2 monitored siren output, general alarm relay, general failure relay, general indicators (Fore, failure, service, CPU failt, general desconnection, in test, fault in sounders circuit), configurable delays, 24V and zone indicators (Alarm, fault, desconnection, test). Batteries not included. Language: Portuguese.
    V.A.T. included
    Consult
    MorleyIAS® Vision LT Conventional Panel - 8 Zones (Portuguese) [VSN8-LT-P]
    MorleyIAS® Vision LT Conventional Panel - 8 Zones (Portuguese)
    Ref.: VSN8-LT-P
    Microprocessed compact fire detection panel of 8 zones. Distinghuises between alarm detector or push buttons by zone. Up to 32 ECO1000 detectors by zone. Includes power supply, 2 monitored siren output, general alarm relay, general failure relay, general indicators (Fore, failure, service, CPU failt, general desconnection, in test, fault in sounders circuit), configurable delays, 24V and zone indicators (Alarm, fault, desconnection, test). Batteries not included. Language: Portuguese.
    V.A.T. included
    Consult
    MorleyIAS® Vision LT Conventional Panel - 4 Zones (Portuguese) [VSN4-LT-P]
    MorleyIAS® Vision LT Conventional Panel - 4 Zones (Portuguese)
    Ref.: VSN4-LT-P
    Microprocessed compact fire detection panel of 4 zones. Distinghuises between alarm detector or push buttons by zone. Up to 32 ECO1000 detectors by zone. Includes power supply, 2 monitored siren output, general alarm relay, general failure relay, general indicators (Fore, failure, service, CPU failt, general desconnection, in test, fault in sounders circuit), configurable delays, 24V and zone indicators (Alarm, fault, desconnection, test). Batteries not included. Language: Portuguese.
    V.A.T. included
    Consult
    MorleyIAS® Vision LT Conventional Panel - 2 Zones (Portuguese) [VSN2-LT-P]
    MorleyIAS® Vision LT Conventional Panel - 2 Zones (Portuguese)
    Ref.: VSN2-LT-P
    Microprocessed compact fire detection panel of 2 zones. Distinghuises between alarm detector or push buttons by zone. Up to 32 ECO1000 detectors by zone. Includes power supply, 2 monitored siren output, general alarm relay, general failure relay, general indicators (Fore, failure, service, CPU failt, general desconnection, in test, fault in sounders circuit), configurable delays, 24V and zone indicators (Alarm, fault, desconnection, test). Batteries not included. Language: Portuguese.
    V.A.T. included
    Consult
    MorleyIAS® Vision LT Conventional Panel - 12 Zones [VSN12-LT]
    MorleyIAS® Vision LT Conventional Panel - 12 Zones
    Ref.: VSN12-LT
    Microprocessed compact fire detection panel of 12 zones. Distinghuises between alarm detector or push buttons by zone. Up to 32 ECO1000 detectors by zone. Includes power supply, 2 monitored siren output, general alarm relay, general failure relay, general indicators (Fore, failure, service, CPU failt, general desconnection, in test, fault in sounders circuit), configurable delays, 24V and zone indicators (Alarm, fault, desconnection, test). Batteries not included. Language: Spanish.
    V.A.T. included
    Consult
    MorleyIAS® Vision LT Conventional Panel - 4 Zones [VSN4-LT]
    MorleyIAS® Vision LT Conventional Panel - 4 Zones
    Ref.: VSN4-LT
    Microprocessed compact fire detection panel of 4 zones. Distinghuises between alarm detector or push buttons by zone. Up to 32 ECO1000 detectors by zone. Includes power supply, 2 monitored siren output, general alarm relay, general failure relay, general indicators (Fore, failure, service, CPU failt, general desconnection, in test, fault in sounders circuit), configurable delays, 24V and zone indicators (Alarm, fault, desconnection, test). Batteries not included. Language: Spanish.
    V.A.T. included
    Consult
    MorleyIAS® Vision LT Conventional Panel - 8 Zones [VSN8-LT]
    MorleyIAS® Vision LT Conventional Panel - 8 Zones
    Ref.: VSN8-LT
    Microprocessed compact fire detection panel of 8 zones. Distinghuises between alarm detector or push buttons by zone. Up to 32 ECO1000 detectors by zone. Includes power supply, 2 monitored siren output, general alarm relay, general failure relay, general indicators (Fore, failure, service, CPU failt, general desconnection, in test, fault in sounders circuit), configurable delays, 24V and zone indicators (Alarm, fault, desconnection, test). Batteries not included. Language: Spanish.
    V.A.T. included
    Consult
    MorleyIAS® Vision LT Conventional Panel - 2 Zones [VSN2-LT]
    MorleyIAS® Vision LT Conventional Panel - 2 Zones
    Ref.: VSN2-LT
    Microprocessed compact fire detection panel of 2 zones. Distinghuises between alarm detector or push buttons by zone. Up to 32 ECO1000 detectors by zone. Includes power supply, 2 monitored siren output, general alarm relay, general failure relay, general indicators (Fore, failure, service, CPU failt, general desconnection, in test, fault in sounders circuit), configurable delays, 24V and zone indicators (Alarm, fault, desconnection, test). Batteries not included. Language: Spanish.
    V.A.T. included
    Consult
    Color Touch Screen for NOTIFIER® NFS-SUPRA [NFS-TFT]
    Color Touch Screen for NOTIFIER® NFS-SUPRA
    Ref.: NFS-TFT
    4.3'' graphic display (480x272 pixels) for NFSx-Supra. Indicates the operating status of the equipment while allowing access to the history in a simple way.
    V.A.T. included
    Consult
    Marco HONEYWELL™ para Montaje en Rack [RACK-SUPRA]
    Marco HONEYWELL™ para Montaje en Rack
    Ref.: RACK-SUPRA
    Accessory for rail mounting, 19" in grey colour for conventional extinction panels VSN-2PLUS serie RP1R-SUPRA and VSN-RP1R-PLUS2. Occupies 8U. Dimensions: 480 x 355 x 125mm.
    V.A.T. included
    Consult
    NOTIFIER® NFS Microprocessed Conventional Panel - 4 Zones [002-477-249]
    NOTIFIER® NFS Microprocessed Conventional Panel - 4 Zones
    Ref.: 002-477-249
    Microprocessed conventional panel with 4 zones with 2 monitored and configurable siren outputs and 2 remote inputs. Allows the connection of 020-713 relay card (Optional). Batteries not included.
    V.A.T. included
    Consult
    NOTIFIER® NFS Microprocessed Conventional Panel - 8 Zones [002-477-289]
    NOTIFIER® NFS Microprocessed Conventional Panel - 8 Zones
    Ref.: 002-477-289
    Microprocessed conventional panel with 8 zones with 2 monitored and configurable siren outputs and 2 remote inputs. Allows the connection of 020-713 relay card (Optional). Batteries not included.
    V.A.T. included
    Consult
    NOTIFIER® NFS Microprocessed Conventional Panel - 2 Zones [002-477-229]
    NOTIFIER® NFS Microprocessed Conventional Panel - 2 Zones
    Ref.: 002-477-229
    Microprocessed conventional panel with 2 zones with 2 monitored and configurable siren outputs and 2 remote inputs. Allows the connection of 020-713 relay card (Optional). Batteries not included.
    V.A.T. included
    Consult
    MorleyIAS® Coverage Expander [MIW-EXP]
    MorleyIAS® Coverage Expander
    Ref.: MIW-EXP
    Coverage expander for MIW systems via radio to improve the covering distance. Occupy an output module direction in the loop and requires an extern power supply of 24VDC 25mA from a certified source in accordance with EN54-4 standard. Provide a double orthogonal antenna to guarantee communications and RS232 port for PC programmation. Can be associated with a maximum of 7 expenders for each MIW-INT interface, 5 are continued connected and up to a maximum of 3 connected to an other MIW-EXP.
    V.A.T. included
    Consult
    SYSAWAY© 2025 All rights reserved