    UTC™ LaserSense® Replacement Filter for HSSD2 (Pack of 6 Pcs.) [9-30699N-P]
    UTC™ LaserSense® Replacement Filter for HSSD2 (Pack of 6 Pcs.)
    Ref.: 9-30699N-P
    Spare filter for LaserSense® HSSD2 detectors.
    V.A.T. included
    338.80 €
    UTC™ LaserSense® Command Module [FHSD8230-09]
    UTC™ LaserSense® Command Module
    Ref.: FHSD8230-09
    Booster Command Module for SenseNet detector network, maximum 127 detectors. Incorporates communications card and programmable serial port for integrtion with text messages (TAP) or BACnet BMS. 5 Relay outputs(Fail, Pre-alarm, Alarm, Alarm2 and Aux). State indicators with leds and LCD. Possibility of connecting in bus SenseNet up to 127 detectors. Incorporates communications card. Optional input/ output FHSD8511 card. Requires power supply of 24V (450mA). Measures: 427x372x95mm. Certificates: CE and CPR (EN54 part 20).
    V.A.T. included
    Consult
    UTC™ ModuLaser® Command Module [FHSD8300]
    UTC™ ModuLaser® Command Module
    Ref.: FHSD8300
    Command module with color TFT screen to create a network of FHSD8300 and FHDS8310 detectors, up to a maximum of 127 aspiration equipment. It is compatible with any combination of ModuLaser, as well as Micra and / or HSSD2. Configuration can be done through the user interface, or through a computer with remote software. It requires a 24V (250mA) power supply. Dimensions: 110.5 x 113.5 x 300 mm. Certificates: CE and CPR (EN54-20).
    V.A.T. included
    2,210.69 €
    UTC™ ModuLaser® Headend Module without TFT Display [FHSD8310]
    UTC™ ModuLaser® Headend Module without TFT Display
    Ref.: FHSD8310
    Capable of controlling eight FHSD8330 laser analysis cameras. It has LED indicators for faults and Alarm, it also has relay or APIC outputs. Configurable through a PC with remote software or through SenseNET with an FHSD8320 Display Command Module. It requires a 24V (250mA) power supply. Dimensions: 110.5 x 113.5 x 300 mm. Certificates: CE and CPR (EN54-20).
    V.A.T. included
    2,462.40 €
    UTC™ Fastening Plate for 1 Reflector Mirror [FD-MB30]
    UTC™ Fastening Plate for 1 Reflector Mirror
    Ref.: FD-MB30
    Clamping plate for 1 reflector mirror (OR2000), with the option of adjustment to the assembly supplement FD-MB20.
    V.A.T. included
    134.70 €
    UTC™ Mounting Bracket for Linear Smoke [FD-MB10]
    UTC™ Mounting Bracket for Linear Smoke
    Ref.: FD-MB10
    Assembly supplement for infrared rays linear smoke detectors, to use with FD700, FD900, FD2700 y FDR-EZn series. Cn be mounted in vertical or horizontal position and allows an adjustment from 0 to 45ºC.
    V.A.T. included
    230.99 €
    UTC™ Reflector Mirror [OR2000]
    UTC™ Reflector Mirror
    Ref.: OR2000
    Reflector mirror for infrared beam reflection barriers.
    V.A.T. included
    92.52 €
    UTC™ Fastening Plate for 4 Reflecting Mirrors [FD-MB40]
    UTC™ Fastening Plate for 4 Reflecting Mirrors
    Ref.: FD-MB40
    Clamping plate for 4 reflector mirrors (OR2000), with the option of adjustment to the assembly supplement FD-MB20.
    V.A.T. included
    158.57 €
    UTC™ Mounting Bracket for Linear Smoke [FD-MB20]
    UTC™ Mounting Bracket for Linear Smoke
    Ref.: FD-MB20
    Assembly supplement for infrared rays linear smoke detectors, to use with FD800 serie and FD-MB30 y FD-MB40 supplements. Can be mounted in vertical or horizontal position and allows an adjustment from 0 to 45ºC.
    V.A.T. included
    264.30 €
    Set of Smoke Optic Detection for UTC™ IR Barrier [FD805R-N]
    Set of Smoke Optic Detection for UTC™ IR Barrier
    Ref.: FD805R-N
    Controller with an auto-adjustable infrared rays linear smoke detector with a maximum range of 50 x 8 metres. Possibility of connecting up to 2 detectors per controller. Power supply 24VDC. Maximum consumption: 36mA. Working temperature: -10ºC to 55ºC. IP54. Measures and weight of the detector: 135x135x135mm. and 0,5Kg. Measures and weight of the controller: 200x235x71mm.and 1Kg. Measures and weight of the reflector: 100x100x9,5mm and 0,07Kg. Certified: CE and CPR (EN54 part 12).
    V.A.T. included
    1,171.52 €
    UTC™ IR Linear Smoke Detector from 10 to 100m Ranging [FD710RVDS]
    UTC™ IR Linear Smoke Detector from 10 to 100m Ranging
    Ref.: FD710RVDS
    Linear smoke detector with infrared beam, by reflection of light in a mirror, with a maximum range from 50 to 100 x 15 metres. Requires external power supply (12 to 24 VDC), maximum consumption 15mA. Certified: CE, VDS and CPR (EN54 part 12).
    V.A.T. included
    1,115.97 €
    UTC™ IR Linear Smoke Detector from 5 to 50m Ranging [FD705RVDS]
    UTC™ IR Linear Smoke Detector from 5 to 50m Ranging
    Ref.: FD705RVDS
    Linear smoke detector with infrared beam, by reflection of light in a mirror, with a maximum range from 5 to 50 x 15 metres. Requires external power supply (12 to 24 VDC), maximum consumption 15mA. Certified: CE, VDS and CPR (EN54 part 12).
    V.A.T. included
    951.04 €
    UTC™ Aritech™ 2000 Series Addressable Reflective Beam Detector 50 - 100 m [FD2710R]
    UTC™ Aritech™ 2000 Series Addressable Reflective Beam Detector 50 - 100 m
    Ref.: FD2710R
    Linear infrared smoke detector, for Aritech™ analogic panels, powered by the loop, by reflection of light in a mirror, with a maximum coverage of 100 x 15 meters. CPD certificate according to standard EN54 part 12.
    V.A.T. included
    1,470.42 €
    UTC™ Aritech™ 2000 Series Addressable Reflective Beam Detector 5 - 50 m [FD2705R]
    UTC™ Aritech™ 2000 Series Addressable Reflective Beam Detector 5 - 50 m
    Ref.: FD2705R
    Linear infrared smoke detector, for Aritech™ analogic panels, supplied by the loop, by reflection of light in a mirror, with a maximum coverage of 50 x 15 meters. CPD certificate according to standard EN54 part 12.
    V.A.T. included
    1,163.86 €
    UTC™ GST® Conventional Ultraviolet Flame Detector [C-9104]
    UTC™ GST® Conventional Ultraviolet Flame Detector
    Ref.: C-9104
    The C-9104 Conventional Ultraviolet Flames Detector senses the ultraviolet (UV) rays emitted by a burning substance and is used in areas where you would expect heat and smoke that would leave the usual option of heat or smoke detectors ineffective, such as generator rooms. Requires DZ-03 or DZ-03D mounting base.
    V.A.T. included
    276.17 €
    UTC™ GST® Digital Explosion Proof Dual IR Flame Detector [DI-9107RExd]
    UTC™ GST® Digital Explosion Proof Dual IR Flame Detector
    Ref.: DI-9107RExd
    Dual-band infrared light detection for fire alarm. Sensitive to flame from material containing carbon. Suitable for fire starting from flame in large indoor or outdoor areas. Addressable (connecting fire alarm control panel) and non-addressable (through relay contact) working modes optional. Flame-proof. Applicable to either commercial or hazardous industrial areas, such as explosive Zone 1 and 2, and Zone 21 and 22 with flammable dust.